GNSS ENGINEERING TOOLS
Cascaded Noise Figure Calculator
Build a receiver front-end chain from gain stages and passive losses. Calculate its noise figure with the Friis formula, compare input-referred noise contributions and export the stage results.
Cascade results
Noise contribution by stage
| Stage | Type | Gain · dB | NF · dB | Cumulative gain · dB | Cumulative NF · dB | Te contribution · K | Added-noise share |
|---|
Friis cascade formula
Fᵢ = 10^(NFᵢ / 10)
Ftotal = F₁ + (F₂ − 1)/G₁
+ (F₃ − 1)/(G₁G₂) + …
NFtotal = 10 log₁₀(Ftotal)
Gtotal(dB) = Σ gainᵢ(dB)
Te = (Ftotal − 1) × 290 K
Each later noise term is divided by all preceding linear power gains. A stage’s own gain affects the weighting of subsequent stages; it does not divide that stage’s own input-referred noise.
The contribution table uses Cᵢ = (Fᵢ − 1)/(G₁…Gᵢ₋₁), with an empty product of 1 for stage 1. Thus Ftotal = 1 + ΣCᵢ, and Te contribution = 290 × Cᵢ.
Passive losses and temperature
G = 1/L; gain(dB) = −loss(dB)
Te,stage = (L − 1) × Tphysical
Fstage = 1 + (L − 1) × Tphysical / 290
Passive mode represents a matched dissipative loss, such as an attenuator or an appropriate equivalent model of a cable or filter. At 290 K its NF in dB equals its loss in dB. At another physical temperature the calculator uses the full expression above.
Zero loss adds no noise in this model. Zero physical temperature is accepted only as the classical mathematical limit. The thermal-loss approximation needs hf ≪ kT; cryogenic and quantum regimes may require another model.
Compare the placement of a loss
The first two examples contain the same 20 dB / 1 dB NF gain stage, a 2 dB passive loss at 290 K and a 20 dB / 5 dB NF gain stage. Moving the loss before the low-noise stage changes the total NF while keeping the total gain at 38 dB.
| Stage order | Total gain | Cascaded NF |
|---|---|---|
| LNA → loss → gain | 38 dB | 1.136239 dB |
| Loss → LNA → gain | 38 dB | 3.073959 dB |
Use the example buttons above to inspect both chains. Front-end gain can reduce later stages’ input-referred noise, but gain selection also needs linearity, blocking and dynamic-range checks.
Use compatible RF parameters
This calculator applies to a matched, linear two-port cascade at one selected frequency or narrow band. It does not combine S-parameters, model impedance mismatch, integrate frequency-dependent NF, or check compression, oscillation or interference. Enter the gain and NF at the actual bias, temperature and frequency of each gain stage.
A mixer’s SSB or DSB noise figure cannot automatically be used as an ordinary gain-stage NF. Image responses and frequency conversion require a suitable equivalent model. ADC quantization and digital processing also need their own noise and bandwidth treatment.
Equivalent input noise temperature describes added noise; it is not the hardware’s physical temperature or the antenna temperature. This tool does not calculate receiver sensitivity or absolute output noise power.
References: Rohde & Schwarz: cold-source noise figure theory, Analog Devices: cascade and mixer noise analysis, and NRAO: receiver noise and attenuator temperature.
Frequently asked questions
How is cascaded noise figure calculated?
Convert each gain and noise figure from dB into linear ratios, apply the Friis cascade formula, then convert the total noise factor back to dB. Later stages are weighted by all preceding gains. Noise figures must not simply be added in dB.
How should I enter a cable, filter or attenuator?
Choose Passive loss, enter a positive loss in dB and its physical temperature in kelvin. The model assigns a negative gain equal in magnitude to the loss and calculates its added thermal noise. NF equals loss in dB only at the 290 K reference temperature under the stated matched model.
Why does stage order change the result?
Noise added by a later stage is referred to the chain input through the gain before it. Moving a passive loss before an LNA changes those weights. Reordering the same stages preserves total gain but can change total noise figure.
What does equivalent input noise temperature mean?
It is the cascade's added noise expressed as Te = (Ftotal minus 1) times 290 K and referred to its input. It excludes the source noise and is not the physical temperature of the receiver. Table percentages describe shares of added noise only.
What if the source noise temperature is not 290 K?
The displayed NF remains referenced to T0 = 290 K. For a source noise temperature Ts, use the input-referred temperature Ts + Te. In the same flat matched classical model, output noise is k B Gtotal (Ts + Te). Multiplying k Ts B by Ftotal is generally incorrect unless Ts equals T0.
Can I enter mixer or ADC specifications directly?
Not automatically. Mixer image bands, SSB and DSB conventions, frequency conversion and ADC quantization need suitable models. This tool evaluates ordinary compatible linear two-port gain and noise parameters; it does not resolve those effects or derive an equivalent model for you.
Planning a GNSS receiver test chain?
Share your receiver, signal band, RF path and measurement goals to discuss a suitable GNSS simulation or validation setup.